Lay mainline trace wire continuously by passing around the outside of valves and fittings on the north or east side.
Tracer wire for water line.
Taping the wire to the pipe helps prevent damage to the wire during back filling or when digging around the pipe in the future.
The coating is normally polyethylene the same.
That s why tracer wire is laid underground with sewer lines.
When other alternatives are used like electrical tape corrosion will result causing your locate signal to stop at the connection point.
A coated copper clad steel tracer wire of 12 gauge or larger kub item 300362 shall be installed with all buried plastic mains and services.
A tracer wire system is only as good as its weakest connection.
Imagine going a day or two days or a week without water.
Tracer wire should not be wrapped around pipe or connectors except at the riser.
They supply high quality wire that will help you complete your projects.
If you are planning on burying the wire 12 gauge insulated copper wire open to the ground at the far end is a great choice.
New tracer wire designed specifically for underground use is no longer solid copper but copper clad steel for better strength to prevent breakage.
Water system a mainline trace wire must be installed with all service lateral trace wires properly connected to the mainline trace wire to ensure full tracing locating capabilities from a single connection point.
Main line splice to service line connection shall be specifically manufactured for use in underground trace wire installation shall be dielectric silicon filled to seal out moisture and corrosion and shall be installed in a manner so as to prevent any uninsulated wire exposure.
That s what could happen if something were to happen to your water pipes and lines.
Tracer wire shall not be taped to the pipe.
The tracer wire shall be laid within 6 inches of the plastic pipe where practical and directly above if possible.
Yellow is for gas orange is for communication blue tracer wire is for potable water and green is for sewer.
Using a spacer taping the tracer wire to the pipe every 8 10 feet in the three o clock position or specifying fill between the pipe and tracer wire are all acceptable practices.
The tracer wire should be placed in the same orientation to all installed pipe.
They have been industry leaders since 1985.
No bare tracer wire shall be exposed either below or above ground.
The red wire is for electric.
Tracer wire shall not be connected to existing foreign conductive utilities.
This wire is what s actually searched for if the pipe itself needs to be located hence the name.
Tracer wire shall not be wrapped around the pipe.
Installation of color coded warning tape one foot above the pipe will enhance utility id during excavation.
Once a pipe is laid down tracer wire is placed along it s length and buried next to the pipe.
Water pipe tracer wire.
Tracer wire which is also called locating wire or locator wire is used to assist in locating pipes and other lines after they ve been buried in the ground.
Luckily tracer wire is used for this application as well.
Exposed ends such as at meter risers are not allowed and shall be protected from exposure.
Since water pipes are found both underground and within buildings and homes tracer wire must be.